PumpForge’s Hydraulics Beside Published Worked Examples
Fire service training documents publish worked pump problems with their answers. Here are some of them, each set beside the answer PumpForge’s simulator gives for the same lay. Where the two differ, we say by how much and why.
How this page is made. The published answers are copied from their sources exactly as printed, and each source is linked at the bottom of the page. PumpForge’s answers are not typed in: they are worked out by the simulator’s own hydraulics code every time this page loads, the same code that sets the correct pump pressure for every drill a trainee runs.
Our figures are shown to one decimal place. The sources often round to the nearest psi, so a gap of under 1 psi is rounding, not a difference in method.
The formulas PumpForge uses
- Pump discharge pressure is nozzle pressure plus friction loss, plus appliance loss, plus or minus elevation.
- Friction loss is C × (gpm ÷ 100)² × (feet ÷ 100), with C at 15.5 for 1¾-inch hose, 2 for 2½-inch, 0.8 for 3-inch and 0.08 for 5-inch.
- Elevation is 0.434 psi a foot, added when the nozzle is above the pump and taken off when it is below.
- A wye or siamese adds 10 psi once 350 gpm or more goes through it, and nothing below that. A master stream appliance or standpipe adds 25 psi.
- These are PumpForge’s Exact figures. Scenarios are graded with fireground math by default: 0.5 psi a foot of elevation (5 psi a floor), friction loss to the whole psi and the pump pressure to the nearest 5 psi. An instructor can set a scenario to Exact.
- With several lines off one pump, each line is worked out on its own. The pump runs at the highest, and every line is scored against its own correct pressure, so the others are gated down.
Pump discharge pressure
Friction loss and nozzle pressure, two lines
Source: Golder Ranch Fire District (Arizona), page 5
Two attack lines off one pump: 150 feet of 1¾-inch hose flowing 150 gpm through a fog nozzle (100 psi), and 200 feet of 2½-inch hose flowing 250 gpm through a smooth-bore nozzle (50 psi).
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| 1¾-inch line | 152.3 psi | 152.3 psi | 100 NP + 52.3 FL |
| 2½-inch line | 75 psi | 75 psi | 50 NP + 25 FL |
Pump to: published 152 psi, PumpForge 152.3 psi. Same answer.
Several lines at different pressures
Source: Golder Ranch Fire District (Arizona), page 6
Three lines: 300 feet of 2½-inch at 300 gpm on a smooth bore (50 psi); 200 feet of 1¾-inch at 150 gpm on a fog nozzle (100 psi); and 200 feet of 1¾-inch at 161 gpm on a ⅞-inch smooth bore (50 psi).
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| 2½-inch line, 300 gpm | 104 psi | 104 psi | 50 NP + 54 FL |
| 1¾-inch line, fog | 169.75 psi | 169.8 psi | 100 NP + 69.8 FL |
| 1¾-inch line, ⅞-inch tip | 130 psi | 130.4 psi | 50 NP + 80.4 FL |
Pump to: published 170 psi, PumpForge 169.8 psi. Same answer.
A wye below 350 gpm
Source: Golder Ranch Fire District (Arizona), page 9
100 feet of 2½-inch hose to a wye feeding two 200-foot 1¾-inch lines at 150 gpm each on fog nozzles (100 psi). 300 gpm goes through the wye, under 350, so the source adds no appliance loss.
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| Pump to each branch | 188 psi | 187.8 psi | 100 NP + 87.8 FL |
Pump to: published 188 psi, PumpForge 187.8 psi. Same answer.
A wye at 350 gpm or more
Source: Golder Ranch Fire District (Arizona), page 9
100 feet of 3-inch hose (2½-inch couplings) to a wye feeding two 200-foot 2½-inch lines at 250 gpm each on smooth bores (50 psi). 500 gpm goes through the wye, so the source adds 10 psi for it.
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| Pump to each branch | 105 psi | 105 psi | 50 NP + 45 FL + 10 appliance |
Pump to: published 105 psi, PumpForge 105 psi. Same answer.
Elevation and a master stream
Source: Golder Ranch Fire District (Arizona), page 11
200 feet of 5-inch hose to a pre-piped ladder raised 80 feet, with a 1½-inch smooth-bore master stream tip at 600 gpm (80 psi) and 25 psi for the master stream appliance.
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| Master stream | 151 psi | 145.5 psi | 80 NP + 5.8 FL + 25 appliance + 34.7 elevation |
Pump to: published 151 psi, PumpForge 145.5 psi. 5.5 psi lower.
The check sheet counts the 80 feet of height at the field figure of 0.5 psi a foot (40 psi). PumpForge uses the exact 0.434 psi a foot (34.7 psi), the figure NWCG gives as the head pressure of water. The rest of the working agrees. An operator who pumps by the 0.5 rule lands about 5 psi above PumpForge's answer.
Elevation
A nozzle 30 feet below the pump.
Source: Golder Ranch Fire District (Arizona), page 7
Published: -15 psi. PumpForge: -13 psi. 2 psi apart.
The check sheet uses 0.5 psi a foot, so 15 psi of gain. PumpForge uses the exact 0.434 psi a foot, so 13.0 psi of gain (NWCG gives both figures, and says the 0.5 rounding allows for extra friction in the hose).
Pump curves
A fire pump is tested at three points: its rated flow at 150 psi, 70% of that flow at 200 psi and half of it at 250 psi. PumpForge’s pump follows the same points, so pushing more water costs pressure the way it does on a real pumper.
These are the points of the annual pump service test in NFPA 1911, now part of NFPA 1910 (2024 edition): rated flow at 150 psi net, 70% of it at 200 psi and 50% at 250 psi.
A 1,000 gpm pump
Source: San Diego Fire-Rescue Department, pump service test table
| Flow | Test pressure | PumpForge’s pump |
|---|---|---|
| 1,000 gpm | 150 psi | 150 psi |
| 700 gpm | 200 psi | 200 psi |
| 500 gpm | 250 psi | 250 psi |
A 1,500 gpm pump
Source: San Diego Fire-Rescue Department, pump service test table
| Flow | Test pressure | PumpForge’s pump |
|---|---|---|
| 1,500 gpm | 150 psi | 150 psi |
| 1,050 gpm | 200 psi | 200 psi |
| 750 gpm | 250 psi | 250 psi |
Worked problems from other regions
State and county fire academies teach the same maths, sometimes with quicker field rules. Here are their worked problems beside PumpForge’s answers. Two of the handouts are no longer on their academies’ own sites, so they are linked to the Wayback Machine’s archived copies, each labelled with the date of its snapshot.
One attack line on a fog nozzle
Source: Connecticut Fire Academy, page 27
100 feet of 1¾-inch hose flowing 150 gpm through a 100 psi fog nozzle. The manual works the friction loss as 34.875 psi and rounds it to 35.
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| 1¾-inch line | 135 psi | 134.9 psi | 100 NP + 34.9 FL |
Pump to: published 135 psi, PumpForge 134.9 psi. Same answer.
One attack line on a smooth-bore tip
Source: Connecticut Fire Academy, page 28
200 feet of 1¾-inch hose with a 15/16-inch smooth-bore tip at 50 psi. The manual works the flow by Freeman's formula, 184.5 gpm, rounded to 185.
| Line | Published answer | PumpForge | PumpForge’s working |
|---|---|---|---|
| 1¾-inch line, 15/16-inch tip | 156 psi | 156.1 psi | 50 NP + 106.1 FL |
Pump to: published 156 psi, PumpForge 156.1 psi. Same answer.
Friction loss in 100 feet of hose
Connecticut Fire Academy
Source: Connecticut Fire Academy, pages 31 and 32
The manual's table of common 1¾-inch friction losses, and its hand method for 2½-inch hose.
| Hose | Flow | Published | PumpForge |
|---|---|---|---|
| 1¾-inch | 95 gpm | 14 psi | 14 psi |
| 1¾-inch | 125 gpm | 24 psi | 24.2 psi |
| 1¾-inch | 150 gpm | 35 psi | 34.9 psi |
| 1¾-inch | 185 gpm | 53 psi | 53 psi |
| 1¾-inch | 200 gpm | 62 psi | 62 psi |
| 2½-inch | 200 gpm | 8 psi | 8 psi |
Every figure matches to within 1 psi.
Utah Fire and Rescue Academy
Source: Utah Fire and Rescue Academy, Know the Flow, Calculating Pump Discharge Pressure (archived copy from the Wayback Machine, snapshot of 10 January 2025)
Quick field rules for each hose size.
| Hose | Flow | Published | PumpForge |
|---|---|---|---|
| 1¾-inch | 150 gpm | 25 psi | 34.9 psi |
| 2½-inch | 250 gpm | 15 psi | 12.5 psi |
| 2½-inch | 350 gpm | 28 psi | 24.5 psi |
| 3-inch | 300 gpm | 9 psi | 7.2 psi |
| 5-inch | 1,000 gpm | 10 psi | 8 psi |
5 of 5 figures differ by 1 psi or more.
These are shortcuts for working in your head. Utah's own coefficient handout lists the same coefficients PumpForge uses, and they give the PumpForge figures.
Montgomery County (Maryland) Fire and Rescue Service
Source: Montgomery County (Maryland) Fire and Rescue Service, page 2, accepted friction loss per 100 feet (archived copy from the Wayback Machine, snapshot of 17 November 2023)
The county's accepted friction loss for 1¾-inch hose.
| Hose | Flow | Published | PumpForge |
|---|---|---|---|
| 1¾-inch | 100 gpm | 10 psi | 15.5 psi |
| 1¾-inch | 150 gpm | 30 psi | 34.9 psi |
| 1¾-inch | 200 gpm | 50 psi | 62 psi |
3 of 3 figures differ by 1 psi or more.
Montgomery County's accepted figures run below the textbook coefficient; its own sheet gives 12Q² for 1¾-inch hose where the textbook gives 15.5Q². PumpForge uses the textbook figure.
Sources
- Golder Ranch Fire District (Arizona), Engineer Practical Check Sheets: Calculating Hydraulics (Theoretical), 28 December 2022. An engineer check sheet that cites NFPA 1002 and uses the same hose coefficients as PumpForge: 15.5 for 1¾-inch, 2 for 2½-inch, 0.8 for 3-inch with 2½-inch couplings and 0.08 for 5-inch.
- National Wildfire Coordinating Group, Firefighter Math: 3.4 Calculating Engine Pump Pressures. Gives 0.434 psi per foot as the exact head pressure of water, and 0.5 psi per foot as the rounded figure used in the field.
- San Diego Fire-Rescue Department, Drill Manual, Chapter 15: Fire Ground Hydraulics (revised February 2023). Its pump service test table: rated capacity at 150 psi, 70% of it at 200 psi and 50% at 250 psi.
- Connecticut Fire Academy, Basic Pump Operations and Hydraulics, Pump Operator student manual (2017). Works friction loss as C × Q² × L with the same coefficients PumpForge uses: 15.5 for 1¾-inch, 2 for 2½-inch, 0.8 for 3-inch with 2½-inch couplings and 0.08 for 5-inch.
- Utah Fire and Rescue Academy, Pumper Driver/Operator course handouts: Know the Flow, and Friction Loss Coefficients - Single Line (archived copy from the Wayback Machine, snapshot of 10 January 2025). Its coefficient handout lists the same single-line coefficients PumpForge uses; Know the Flow teaches quicker field rules, which land a few psi either side of it. The coefficient handout (archived copy from the Wayback Machine, snapshot of 5 December 2025).
- Montgomery County (Maryland) Fire and Rescue Service, Driver Certification Program, Module 3: Hydraulics References (May 2020) (archived copy from the Wayback Machine, snapshot of 17 November 2023). Its accepted friction loss figures for 1¾-inch hose run below the textbook coefficient of 15.5; the same sheet gives 12Q² for 1¾-inch hose.
Want to run your own numbers? The free pump discharge pressure calculator uses the same formulas, and Real Hydraulics covers the rest of the simulator.
Check the hydraulics on a pump panel
Run these lays on the simulator with your own crew, free for 30 days.